• 230V 120V Rail Control High Magnetic Flux Electrical Transformer
  • 230V 120V Rail Control High Magnetic Flux Electrical Transformer
  • 230V 120V Rail Control High Magnetic Flux Electrical Transformer
  • 230V 120V Rail Control High Magnetic Flux Electrical Transformer

230V 120V Rail Control High Magnetic Flux Electrical Transformer

Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio, LED Lamp, Equipment
Phase: Single
Core: Core-type Transformer
Samples:
US$ 0.8/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
230V 120V Rail Control High Magnetic Flux Electrical Transformer pictures & photos
230V 120V Rail Control High Magnetic Flux Electrical Transformer
US $0.6-1 / Piece
Min. Order: 100 Pieces
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Tianjin, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (22)

Basic Info.

Model NO.
GWHF
Cooling Method
Dry-type Transformer
Winding Type
Separated Winding Transformer
Certification
ISO9001-2000, UL, ISO9001, CCC, CE
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Transformer for Microcomputer Equipment
Frequency Characteristics
High Frequency
Shape of Core
Grewin High Frequency Transformer
Brand
Grewin High Frequency Transformer
Electronic Transformer Color
Yellow, Black
Frequency Electronic Transformer
Higher Than 20kHz-200kHz
Transformer Materials
High Magnetic Flux and Low Loss Magnetic Materials
Electronic Transformer Application
PCB Circuits, Computer, TV, Monitor, Scanner
Insulation
UL Insulation System for Class B (130), F (155)
Magnetic Electronic Transformer
EPC Ep DC Power Magnetic Transformer
Features
Low Transmission, Strong Anti-Interference, Dist
RM Etd Ee Electronic Transformer
Windely Used Fax Machines, PBX
Efd25 Epcs Ee65 RM10 Transformer
DC Magnetic Transformer for Electrical Microwave
High Frequency Transformer Models Sereis
Ee, Etd, Efd, Er, Ep, Ec, RM, Pq, pH etc.
Transport Package
Export Standard Carton with Strong Pallet
Specification
VDE, CE
Trademark
Grewin transformer
Origin
Tianjin
HS Code
85045000
Production Capacity
100000 /Month

Product Description

Flyback Transformer Voltage Electrical Transformer for Power Switching supply

1. Their input voltage can be different to meet requirements of various regions: AC380V-240V-230V-220V-120V-110V-100V.

2. Special designs are also available to meet customers' requirements.

Power Capacity Chart:
Power range (W)Core type using N67* grade material
<5RM4; P11/7; EF12.6; U10
5-10E(F)16; RM5; P14/8
10-20RM6; E(F)20; P18; U15; EFD15
20-50RM8; P22; RM10 ETD29; E25; EFD20
50-100ETD29; ETD34; RM12; P30; EFD25
100-200ETD34; ETD39; ETD44; P36; E30; E42; EFD30
200-500ETD44; ETD49; E55
>500ETD54; ETD59; E65
PQ20. PQ32. PQ35 etc.

The power capacity of each core type varies due to differences in topology, operating frequency and temperature, flux density, and material grade.
* Siemens material grade 

ETD type Transformer Parameters

Model

Output power : W
 

ETD29

30-90

ETD34

30-90

ETD39

20-500

ETD44

20-800

ETD49

20-800

ETD59

400-2000

Other Related High Frequency Transformer Parameters:

Table1: EE type Transformer Parameters

 
EE type transformer
Part No. Terminal
  Pins
Dimension mm Type Electrical parameter
A B C Inductance Output power(W)
EE-8.3 6 8.0 8.0 8.3 V 100.0uH 0.2-3.0
EE-10 8 11.5 10.2 10.2 V 80.0uH 0.5-5.0
EE-13 10 12.0 12.5 13.0 V 120.0uH 0.5-8.0
EE-16-1 6 14.8 13.3 16.0 V 90.0uH 1.0-10.0
EEL-16 10 28.5 16.0 21.9 V 600.0uH 2.0-15.0
EE-19-1 8 17.6 16.0 19.0 V 800.0uH 3.0-30.0
EEL19 10 31.5 16.0 21.1 V 1200.0uH 3.0-30.0
EE-25-1 6 20.0 18.2 25.2 V 2000.0uH 3.0-45.0
EEL25 8 35.3 17.5 25.2 V 2800.0uH 3.0-45.0
EE-30 10 21.0 29.2 30.0 H 900.0uH 3.0-50.0
EE-40 14 27.6 30.5 40.0 H 1500.0uH 3.0-55.0
EE-42/15-1 12 33.8 44.0 42.0 H 2000.0uH 3.0-80.0
EE-42/20-1 12 45.0 39.8 42.0 V 1900.0uH 3.0-90.0
EE-55 20 50.0 50.0 55.0 H 3000.0uH 3.0-150.0
EE-65 16 55.2 51.8 65.0 H 4500.0uH 3.0-300.0
 

Table2:EPC type Transformer Parameters

Model Dimension (mm) VA Weight
A B C f=50KHz f=100KHz g
EPC-9.5 10 5.5 10 1.1 2.5 9
EPC-13 14 9 14 5 8 11
EPC-17 19 11 18 14 20 18
EPC-19 20 13 21 18 27 21
EPC-25 27 17 26 36 59 29
EPC-27 29 17 36 52 75 35

Table3: ER type Transformer Parameters
 
ER Transformer Specification
Model PIN Dimension
A B C+/-0.5 D+/-0.5 E F
ER25.5 8 19.5 19.7 12.5 4 5 25.5
ER28 12 30.5 23 17.5 4 5 31
ER28 12 23.1 28.2 25 4 5 29.1
ER28 12 36 27 20 4 5 30
ER28 12 26.3 37.1 30 4 5 30.2
ER33 14 37.5 28 22.5 4 5 36
ER35 14 43.5 28 22.5 4 5 35.5
ER35 16 29.1 40.3 35.4 4 5 40.3
ER39 16 46 31.1 25 4 5 43.1
ER39 16 33 41.5 30.85 4 7.5 42.3
ER40 16 48 31.1 25 4 5 43.1
ER4215 14 45.5 30 25 4 5 42
ER4220 14 44 37.5 36 4 5 42

Table4: PQ type Transformer Parameters
 
COILFORMER DIMENSIONS (mm)

TYPE

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

PQ20/16

23.15

17.35

23.15

20.3

2.5

9

3.8

5.1

17.9

9.7

7.82

10.8

2.4

0.6

7.35

PQ20/20

23.15

17.35

23.15

20.3

2.5

9

3.8

5.1

22

13.85

12

10.8

2.4

0.6

7.35

PQ26/20

26.6

21.85

29.75

25.4

-

12.3

3.8

7.6

21.5

11.05

9

14.2

2.4

0.65

7.2

PQ26/25

26.6

21.85

29.75

25.4

-

12.3

3.8

7.6

26.05

15.65

13.55

14.2

2.4

0.65

7.2

PQ32/20

32.15

26.7

34.3

30.5

-

13.85

5.1

7.6

22.35

11.05

8.9

15.9

2.8

0.75

7.2

PQ32/30

32.15

26.7

34.3

30.5

-

13.85

5.1

7.6

32.15

20.85

18.7

15.9

2.8

0.75

7.2

PQ35/35

35.00

31.0

39.0

-

-

15

-

-

37.4

-

22.4

16.9

-

1

5


1).Features:
 Has a strong anti-interference, distributed capacitance, impedance, attenuation of low transmission, firm
structure,can fine-tune the inductance, etc., are widely used in fax
machines, PBX.

 
2). Applicable frequency range: 20 to 100kHz :
Operating frequency: higher than 200kHz
High magnetic flux and low loss magnetic materials
With low leakage inductance and high efficiency .

 3).Applications:

 1.PCB circuits
2.,computer, TV,
3.monitor, scanner,
4.duplicator, mobile adapters,
5.printer and other equipments and
instruments.
UL insulation system for Class B (130), F (155), H (180)

4). Can make other customized Ferrite transformers:
230V 120V Rail Control High Magnetic Flux Electrical Transformer
Power range: core type using N67 grade material
<5: RM4, P11/7, EF12.6 and U10
5 to 10: E (F) 16, RM5 and P14/8
10 to 20: RM6, E (F) 20, P18, U15 and EFD15
20 to 50: RM8, P22, RM10 ETD29, E25 and EFD20
50 to 100: ETD29, ETD34, RM12, P30 and EFD25
100 to 200: ETD34, ETD39, ETD44, P36, E30, E42 and EFD30
200 to 500: ETD44, ETD49 and E55
>500: ETD54, ETD59 and E65



Table4: EFD type Transformer Parameters
230V 120V Rail Control High Magnetic Flux Electrical Transformer
Model  Pin Dimension
A B C D E
EFD-12 8 6 17 20 3.0  13.5
EFD-15 10 7.3 18.2 21.35 2.5 15
EFD-15 10 7.5 19.3 22.6 3.0  16.7
EFD-20 10 9.4 25.3 27.7 3.75 21.7
EFD-20 12 9.7 24 26.8 3 20
EFD-25 10 13.4 29.7 35.4 5 25
EFD-25 10 12.6 29.7 31.5 5 25
EFD-30 12 12.6 31.6 35.5 5 30

5)Advantage:
1.UL, CUL, CE,IEC ISO9001:2015
2.We offer custom-made transformers, OEM and ODM are welcome
3.We deliver the quality you expect at consistently competitive prices
4.Transformer quality lifetime:10 Years.
5.Specialty Sales service:5 -10 Years
6.Transformers Test: 100% test before the shipment

1).Features:

 Has a strong anti-interference, distributed capacitance, impedance, attenuation of low transmission, firm

structure,can fine-tune the inductance, etc., are widely used in fax

machines, PBX.

2). Applicable frequency range: 20 to 100kHz :

Operating frequency: higher than 200kHz
High magnetic flux and low loss magnetic materials
With low leakage inductance and high efficiency .

 3).Applications:

PCB circuits, computer, TV, monitor, scanner, duplicator, mobile adapters, printer and other equipments and instruments.UL insulation system for Class B (130), F (155), H (180).

230V 120V Rail Control High Magnetic Flux Electrical Transformer

4). Can make other customized Ferrite transformers:

Power range: core type using N67 grade material
<5: RM4, P11/7, EF12.6 and U10
5 to 10: E (F) 16, RM5 and P14/8
10 to 20: RM6, E (F) 20, P18, U15 and EFD15
20 to 50: RM8, P22, RM10 ETD29, E25 and EFD20
50 to 100: ETD29, ETD34, RM12, P30 and EFD25
100 to 200: ETD34, ETD39, ETD44, P36, E30, E42 and EFD30
200 to 500: ETD44, ETD49 and E55
>500: ETD54, ETD59 

5)Technical capabiliies:

Over 50 sets toroidal/annular coil winding machines, 3 EI type transformer lines,2 sets of vacuum annealing furnaces.
6)Advantage:
1.UL, CUL, CE, ISO9001:2008
2.We offer custom-made transformers, OEM and ODM are welcome
3.We deliver the quality you expect at consistently competitive prices
4.Transformer quality lifetime:10 Years.
5.Specialty Sales service:5 -10 Years
6.Transformers Test: 100% test before the shipment


7)About us:

1). Tianjin Grewin Technology Co.,ltd. has always laying great emphasis on our core business philosophy "Quality and Honesty First ".

2)product procedure:
The following picture showed you about all finished transformer production line and package with export standard carton and strong pallets:

230V 120V Rail Control High Magnetic Flux Electrical Transformer


3).Terms of Shipment:
Within 10 working days after received related prepayment or L/C.
 

4).Payment terms:

(1). T/T 100% or 50% deposit by T/T in advance, balance amount to be paid 7 days before

delivery.

(2). By irrevocable L/C at sight, to be issued immediately against confirmed order.

(3). Payment by T/T, if order amount is less than USD 20,000.


5).Flow chart of trading activities:
 

NO

Step

Days need

1

Request for quotation

1 day

2

Making quotations

1 day

3

Offer and counter offer

3 days

4

Sending and receiving samples

3-10 days

5

Sample confirmation

3 days

6

Placing a firm order

1 day

7

Paying and receiving the down payment

1-4 day

8

Factory production & Quality inspection

15-20 days

9

Paying and receiving the balance

4 days

10

Delivery of goods

1 days

230V 120V Rail Control High Magnetic Flux Electrical Transformer

230V 120V Rail Control High Magnetic Flux Electrical Transformer

230V 120V Rail Control High Magnetic Flux Electrical Transformer

PLZ Contact us:


TIANJIN GREWIN TECHNOLOGY CO.,LTD

Tel: +86-22-84943756
 
Web: transformer.en.made-in-china.com
 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now