Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode

Product Details
Customization: Available
Connectors: USB
Test Mode: Tdr, Icm,MIM
Still deciding? Get samples of US$ 2400/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (22)
  • Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode
  • Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode
  • Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode
  • Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode
  • Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode
  • Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode
Find Similar Products

Basic Info.

Model NO.
PCLC-901D
Usage
Digital Cable Tester, Multi-Functional Energy Meter
Test Region
100km
Cable Type
Single Core or Three Cores
Certification
CE, RoHS, Ce, RoHS
Customized
Customized
Color
Orange
Sampling Frequency
200MHz
Gain Range
0-70dB
Low Voltage Impulse Voltage
32V
Max.Resolution
0.4m
Locating Range
100km
Dead Zone
2m
Dim.
274*218*81mm
Weight
3.5kgs
Display
Digital
Transport Package
Export Standard Carton or Customize Strong Pallet
Specification
PCLC-901D Cable Fault Pre-locator
Trademark
GREWIN
Origin
China
HS Code
9028901000
Production Capacity
500 PCS Per Month

Packaging & Delivery

Package Size
27.00cm * 22.00cm * 8.00cm
Package Gross Weight
3.500kg

Product Description

Name:  PCLC-901D Power Testing meter/ Cable Fault Pre-locator
 
Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode


Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode


FUNCTION FEATHER:
  1. Multiple distance locating method:
-Low current impulse method: apply to the locating of the low resistance fault. Short circuit fault, open circuit fault. It also can be used in the measurement of the cable length, the intermediate joints, T joints, and cable termination joint. This method also can be used to correct the wave velocity.
-Impulse current method: apply to the high resistance fault, breakdown fault. Use the current coupler to gather signal from the earth wire  
-Multiple impulse method: improvement of the SIM method
  1. 200MHz real-time sampling
-Advance tech.Upgrading for SIM method
-Max. 0.4m measurement resolution,PCLC 750 has small blind zone and is special for the short cable and nearly-terminal fault cable
  1. Touch screen and press key operation
-Touch operating screen with smart gesture operation
-Support cursor drag-drop function and double-click function,easy to locate
-Simple function menus with high performance.
  1. Big color LED screen, friendly interface
-Simple function menus with high performance
  1. 7" LED screen,160°viewing angle,bright with 750cd/m2 to view under sunshine
-PIP copy(pic. temporary storage). There'll be a main window and three temporary storage windows could check three waveform together.
  1. Waveform storage and PC communication
-Special software management for software upgrade, backup and restore in device.
-Waveform storage and communication with computer.
-Internal storage of waveform.
-Optional mini printer for waveform printing
-Support connection with PC or laptop
  1. Power management
-Back light weakens if no operation in 2 min and power off in 10 min. if no operation. 
-Built-in Polymer Lithium-ion battery. 
-Working time could reach 7 hours for each use.


MAIN UNIT PANEL:
Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode

Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode

Details:
l. LED screen : Display all the information. Will introduce in the following.
2.Signal port: connect with testing wire. Choose different wires under different testing mode.
3.Charging port:connect with wire for built-in battery
4.USB disk:save or import waveform
5 Multiple function button:total five functions,up,down,left,right and enter.Up and down button is used for gain adjustment,left and    right button is used for cursor adjustment, and enter is used to switch the dotted cursor and soiled cursor 
6. Power indicator light:it will light when power on 
7.Power/Menu : Turn on or off the machine.When power on,it's menu button.Short press into the menu,press again to exit.
8.Test button:Press to test.

Menu introduction
Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode
Support both touch screen operation and Mechanical button. The operation is easy, flexible and direct.   
Pop-up menu operation:
Main menu includes Range,VOP,Ratio,Scaling,Copy, Staff, Docu. And Operate.
Sub-menu will pop-up when press above button. After operation or click other position of the screen will exit sub-menu.
Press  Power/Menu or Sub-menu will enter the menu mode,and now user could use the multiple function button to operate.
Press  Power/Menu again to exit.
Below is the introduction of main-menu button and their sub-menu details:
Main menu Submenu
Range 200m,400m,800m,1.5km,3km,6km,12km,25km,50km,100km 
VOP XLPE cable,oil paper cable,plastic cable,VOP+,VOP-
Scale Global,zoom in,zoom out
Copy 1/2/3 zone copy,1/2/3 zone compare
Staff Scale switch,new staff,contact setting,fault setting,full length setting,contact delete
Docu. Local storage,USB disk storage,main unit to USB,docu.recall
Operate system setting,screen correct
Operation example:
Observe the waveform,seems the fault point may located on the first half of the waveform,so the distance 1.5km range is too large and then adjust the distance to 400m.
Touch operation as below:
Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode

Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode

Function
Locating methods:  l  Low voltage impulse method 
l  Impulse current method 
l  Multiple impulse method if matched with PCLC-910D 
Sampling frequency:  200MHz 
Gain range:  0-70dB 
Low voltage impulse voltage:  30V 
Max.resolution:  0.4m 
Locating range:  100km 
Dead zone:  2m 
Battery:  Nickel-metal hydride rechargeable batteries,endurance time over 5 hours 
Communication interface:  USB 
Power supply:  Input AC220V,50Hz,current 2A,charge for 8 hours 
Dim.:  27421881mm 
Weight:  3.5kgs 
Operating Temperature:  -10∩-40∩ 
Humidity:  5-90%RH 
Elevation:  <4500m 
 
Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode


Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode

 
 
 
Contact information:
 

Pclc-901d Power Testing Cable Fault Pre-Locator with Tdr Icm MIM Mode
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More