Customization: | Available |
---|---|
Application: | Power, Electronic, Instrument, Lighting, Rectifier, Audio, Communication, Machine Control |
Phase: | Single |
Still deciding? Get samples of US$ 12.5/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Wire leads Toroidal Transformer for Communication
Toroidal Transformer I | |||||||
Power | Thermal Fuse | Current Fuse | Dimension (mm) | Approval Mark | |||
GWB25VA | 135ºC 250V 2A | 250V T 2A | 80*35 | CE UL TUV CQC | |||
GWB30VA | 135ºC 250V 2A | 250V T 2A | 83*35 | CE UL TUV CQC | |||
GWB40VA | 135ºC 250V 2A | 250V T 2A | 87*35 | CE UL TUV CQC | |||
GWB50VA | 135ºC 250V 2A | 250V T 2A | 93*34 | CE UL TUV CQC | |||
GWB60VA | 135ºC 250V 2A | 250V T 2A | 93*35 | CE UL TUV CQC | |||
GWB80VA | 135ºC 250V 2A | 250V T 2A | 102*35 | CE UL TUV CQC | |||
GWB105VA | 135ºC 250V 2A | 250V T 2A | 114*38 | CE UL TUV CQC | |||
GWB120VA | 135ºC 250V 2A | 250V T 2A | 113*41 | CE UL TUV CQC | |||
GWB140VA | 135ºC 250V 2A | 250V T 2A | 114*42 | CE UL TUV CQC | |||
GWB150VA | 135ºC 250V 2A | 250V T 2A | 117*43 | CE UL TUV CQC | |||
GWB160VA | 135ºC 250V 5A | 250V T 5A | 120*43 | CE UL TUV CQC | |||
GWB180VA | 135ºC 250V 5A | 250V T 5A | 125*42 | CE UL TUV CQC | |||
GWB200VA | 135ºC 250V 5A | 250V T 5A | 124*49 | CE UL TUV CQC | |||
GWB220VA | 135ºC 250V 5A | 250V T 5A | 127*50 | CE UL TUV CQC | |||
GWB240VA | 135ºC 250V 5A | 250V T 5A | 129*48 | CE UL TUV CQC | |||
GWB250VA | 135ºC 250V 5A | 250V T 5A | 130*52 | CE UL TUV CQC | |||
GWB260VA | 135ºC 250V 5A | 250V T 5A | 130*53 | CE UL TUV CQC | |||
GWB280VA | 135ºC 250V 5A | 250V T 5A | 138*45 | CE UL TUV CQC | |||
GWB300VA | 135ºC 250V 5A | 250V T 10A | 138*54 | CE UL TUV CQC | |||
GWB320VA | 135ºC 250V 5A | 250V T 10A | 138*54 | CE UL TUV CQC | |||
GWB340VA | 135ºC 250V 5A | 250V T 10A | 138*54 | CE UL TUV CQC | |||
GWB360VA | 135ºC 250V 5A | 250V T 10A | 142*55 | CE UL TUV CQC | |||
GWB380VA | 135ºC 250V 5A | 250V T 10A | 146*54 | CE UL TUV CQC | |||
GWB400VA | 135ºC 250V 5A | 250V T 10A | 148*56 | CE UL TUV CQC | |||
GWB420VA | 135ºC 250V 5A | 250V T 10A | 148*56 | CE UL TUV CQC | |||
GWB440VA | 135ºC 250V 5A | 250V T 10A | 148*60 | CE UL TUV CQC | |||
GWB460VA | 135ºC 250V 5A | 250V T 10A | 149*64 | CE UL TUV CQC | |||
GWB480VA | 135ºC 250V 5A | 250V T 10A | 153*59 | CE UL TUV CQC | |||
GWB500VA | 135ºC 250V 5A | 250V T 10A | 155*62 | CE UL TUV CQC |
Toroidal Transformer | |||||||
Power | Dimension (mm) | Efficiency % | Current | Weight | |||
GWB20VA | 60*25 | >82 | 10mA | 1.200.45kgs | |||
GWB30VA | 65*35 | >84 | 10mA | 1.200.50kgs | |||
GWB50VA | 70*40 | >88 | 20mA | 1.151.30kgs | |||
GWB100VA | 85*60 | >90 | 30mA | 1.151.50kgs | |||
GWB120VA | 90*75 | >93 | 40mA | 1.102.00kgs | |||
GWB200VA | 110*80 | >93 | 100mA | 1.102.80kgs | |||
GWB300VA | 120*80 | >94 | 150mA | 1.083.50kgs | |||
GWB500VA | 130*80 | >94 | 150mA | 1.085.00kgs | |||
GWB800VA | 140*85 | >94 | 200mA | 1.086.50kgs | |||
GWB1000VA | 140*85 | >95 | 300mA | 1.058.50kgs | |||
GWB1500VA | 160*90 | >95 | 400mA | 1.0512.0kgs | |||
GWB2000VA | 180*90 | >95 | 400mA | 1.0515.0kgs | |||
GWB4000VA | 220*95 | >95 | 500mA | 1.0520.0kgs | |||
GWB6000VA | 250*95 | >95 | 500mA | 1.0525.0kgs |
High efficiency Toroidal Transformer
Product description:
Medical Toroidal transformer:
Medical Equipment: Beyond the Toroidal Transformer has a common transformer function,
its anti-electric strength and resistance to damp heat capacity far higher than the national standards and
industry standards.
Additionally oriented towards the requirements of EN 60601
Safety Temperature Limiter recommended
Security Value specified
In many cases with statically shield winding to discharge capacitively coupled
interferences, or to monitor the insulation
Especially low leakage current, which clearly under-runs the required norms(<<5 mA )
Strengthened or enhanced insulation
At minimum equipped with basic insulation
eightened creepage distance and sparking distance in air
Reduced inrush current
Features:
They should pay attention to the air clearance, leakage current, test voltage etc. We use the advanced machine to make sure the windings are very good performance. It should avoid the cables' broken during the production.All the wire harnesses, product enclosures etc whould be treated very carefully.
Application:
Medical grade isolation transformers are installed in medical devices used in hospitals, medical research facilities, and biomedical companies throughout the world. Our medical toroidal transformers are strictly monitored under safety rules, guidelines and governing laws.
2.toroidal transformer for audio technology
Features:
1. Especially low-hum and low-dispersing construction, Low-level of induction
High-grade design casing possible,Statically shield winding and magnetical shield winding optional.
2. Low noise transformer designs will meet your audio needs.
3. In an audio application, unfiltered noise or unwarranted harmonic distortions can produce signal spikes that will affect the overall sound quality. Our unique Quiet designs will provide a long term solution for your audio needs, while not sacrificing overall size and cost.
4. More than ten years experience in this industry, our engineers will work closely with your team and develop the best solution for your audio application.
General Data:
1.Rated input voltage 230 Vac
2.Rated output voltage 2 x 12 - 2 x 35 Vac
3.Power 15 - 625 VA
4.Insulation class B
5.Maximum ambient temperature 40 °C
6.Efficiency up to 95 %
7.Degree of protection IP 00
Advantages:
1.Minimum size at high output
2.Low weight
3.Double output voltage for series or parallel connection
4.Protected against overload by integral temperature fuse
5.Minimal no-load losses
6.Outstanding temperature behaviour thanks to low magnetic leakage field
7.Very low noise field
Application:
Power amplifier / Line Level Preamplifier / Acoustic Monitor / Power Conditioner Aktive subwoofer / UniField Speaker / Loudspeaker / Center speaker Powered subwoofer system / Indoor Or Outdoor Bookshelf Speakers / Home audio
Receivers / Theater amplifiers / Zone amplifiers / Multi-room amplifiers / Network amplifiers / Art speakers
3.toroidal transformer for UPS power supply
Features:
1.Low magnetic leakage
2.Low no-load losses
3.Low mechanical hum
4.High efficiency
5.High-performance
6.Light weight ,compact size
7.Low temperature rise
8.Running a good performance
9.Low magnetic interference
10.Minimum stray magnetic field,Easy to install.
Application:
1.UPS Power Supply.
2.Power amplifier
3.Electric control
4.Medical equipment
5.Telecommunications
6.Instrument
7.Automatic control equipment
8.Outdoor light
9.Audio device.
10.Mechanical equipment
4.toroidal transformer for solar technology
Purpose to describe:
Toroidal transformers of highest quality, alligned for inverter application.
1.Especially high degree of efficiency
2.Low temperature increase
3.Low noise development
4.Compact built
5.Individual configuration
Features:
1.Low tempreture rise (65ºC Max)
2.Single-phase toroidal transformers, power range from 0.8VA to 10000VA
3. Designed and tested according to EN61558. Suitable for installation in electronically equipments, medical equipment etc
4.Short circuit and overload protected withthermal fuse on primary side.
5.Up to 50% less weight than a similar conventional transforme
6.Low magnetisation currents and no-load losses.
Application:
1.Solar Energy Generating Systems
2.Stepper motor supply
3.Inverter and converter.
4.Servo motor supply
5.Wind power generation system
6.Community Antenna Television equipment
7.Satellite television receiving equipment
4.Minature Toroidal Transformer 2.5VA-25vaNO | Step | Days need |
1 | Request for quotation | 1 day |
2 | Making quotations | 1 day |
3 | Offer and counter offer | 3 days |
4 | Sending and receiving samples | 3-10 days |
5 | Sample confirmation | 3 days |
6 | Placing a firm order | 1 day |
7 | Paying and receiving the down payment | 1-4 day |
8 | Factory production & Quality inspection | 15-20 days |
9 | Paying and receiving the balance | 4 days |
10 | Delivery of goods | 1 days |