Product: 0.1A-1000A 0.333mv Current Clamp Transformer with ETL IEC Approval
Current probe(specifications) |
Rated Primary current |
0.1A-1000A |
Output signal |
mA/A or mV/A |
Maximum Non-Destructive Current |
2000A |
Basic Accuracy |
1% |
Safety |
CAT III 600V |
Dielectric Resistance |
1000MOhms @ 500 Vdc |
Case Material |
Polypropylene resinUL flame retardant rating 94-V0 |
Voltage rank |
600Vac(isolated condition), 30Vac(bareness condition) |
Maximum voltage |
600Vac |
Useable frequency |
10Hz - 100kHz |
Maximum Cable Diameter |
2.05 inches (52 mm) |
Dimensions |
4.37x8.5 x1.77 in. (111x216x45 mm) |
Operating Temperature |
-10ºC to +50ºC |
Standard |
IEC 60044-1 |
Accessories |
Supplied with feet for base mounting if required |
Certification |
RoHS compliant CE&ETL approved |
Current probe(features) |
Good appearance |
Low cost |
5 standard sizes |
Clamp-on core design,safer,easier installation, portable |
Both Silicon Steel & Nickel Alloy cores available |
Current or three specs voltage output signal |
Current probe(applications) |
Current, power energy,monitoring devices |
Power Factor Correction devices |
Oscilloscope and harmonic waves analyzer |
Part number |
Input current |
Rated Output |
Frequency
(Hz) |
Secondary
Burden
Resistance |
Accuracy
Class |
GWCTP1535 |
0.5-1000A |
1mA/A |
40-1KHZ |
≤10 Ohms |
1% |
400-1000A |
5A,1A |
50/60HZ |
≤2VA |
1% |
0.1-10A |
100mV/A |
10-1000K |
≥100KOhms |
3%±10mV |
0.1-100A |
10mV/A |
2%±5mV |
1-1000A |
1mV/A |
1%±1mV |
0.5-1000A |
4-20mA |
50/60HZ |
≤100 Ohms |
1% |
|
Rated Input/A |
Output/mA/V |
Accuarcy |
GWSCCT691C-010 |
0.5-100A |
0.333V/0-50mA |
0.2,0.5,1.0 |
GWSCCT691C-016 |
1-250A |
0.333V/0-100mA |
0.2,0.5,1.0 |
GWSCCT691C-025 |
5-400A |
0.333V/0-200mA |
0.2,0.5,1.0 |
GWSCCT691C-036 |
5-630A |
0.333V/0-200mA/1A |
0.2,0.5,1.0 |
GWSCCT691C-050 |
5-1000A |
0.333V/0-500mA/1A/5A |
0.2,0.5,1.0 |
GWQCT03 Clamp sensor Specification
Technical datas:
Rated primary current: |
Max 500A AC |
Output voltage: |
333 mV AC |
Amplitude accuracy: |
±0.5% rdg.±0.1%f.s. (f.s.:500A, 45Hz - 66Hz, Primary conductor in the enter) |
Phase accuracy |
±1°(10~100%I1n)(45 Hz - 5 kHz) |
The amplitude frequency characteristic |
±1% (45 Hz - 5 kHz) ( Deviation Accuracy) |
Conductor impact |
±0.5%(off-center) |
The influence of external electromagnetic fields |
≤0.1 A(in AC 400A /M electromagnetic fields) |
Maximum input current |
550A AC continuous (45-66 HZ Ambient temperature 50°C) |
Temperature coefficient |
0.02 %reading data /°C |
Dielectric strength |
5312 V ACrms /continuous 15s (circuits- core) |
Maximum rated voltage |
600V ACrms |
Woring temperature& humidity |
0 to 50°C (32 - 122°F), ≤80%RH (No condensate) |
Woring temperature& humidity |
-10 to 60°C (14 - 140°F), ≤80%RH (No condensate) |
Indoor using and up to 2000m above sea level |
Standards |
sacurity:EN61010 - 2 -032:2002 , CAT III,contamination II EMC:EN61326:1997+A1:1998+A2:2001+A3:2003(Class A) |
Measure conductor diameter |
≤Φ46mm |
Cable length |
2m |
Size |
About 78W x 160H x 40D mm(excluding protruding parts) |
weight |
About 380g |
Accessory |
Instrution manul one piece |
f.s. :Maximum display datas or scale length
rdg:Reading value (the value of the current is measured and displayed in the measurement of the product)
We can produce following similar clamp on current transformer:
TIANJIN GREWIN TECHNOLOGY CO.,LTD
Add:Meinian Plaza.No.16 Dongting Road,Hexi Distr,Tianjin,China .