5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Single
Still deciding? Get samples of US$ 6.5/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (22)
  • 5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
  • 5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
  • 5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
  • 5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
  • 5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
  • 5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
Find Similar Products

Basic Info.

Model NO.
ct sensor
Core
Core-Type Transformer
Cooling Method
Dry-Type Transformer
Winding Type
Multi-Winding Transformer
Certification
ISO9001-2000, UL, ISO9001, CCC
Usage
Single-Phase Transformer
Frequency Characteristics
50-60Hz
Shape of Core
Toroidal
Brand
Grewin
Rated Primary Current
100-5000AAC
Rated Secondary Current
5 or 1AAC
Rated Load
1, 2.5, 5.0, 10, 30va
Accuracy
0.5, 1.0, 3.0 Class
Rated Short-Time Thermal Current (Ith)
20in
Rated Dynamic Current (Idyn)
2.5ith
Case Material
UL Flame Retardant Rating 94-V0
Highest Voltage for Equipment Um (RMS
720 VAC
Rated Power-Frequency Withstand Voltage
3, 000 VAC
Frequency Range
50/60Hz
Transport Package
Export Standard Cartons with Strong Pallets
Specification
CE
Trademark
grewin
Origin
China
HS Code
850450000
Production Capacity
50000 PCS /Week

Product Description


5 or 1Aac 1, 2.5, 5.0, 10, 30VA 0.5, 1.0 split transformer CT sensor for Protection relays

5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
 

GWSCCT Series Split Core Current Transformer  (Specifications)
Rated Primary current 100-5000Aac
Rated Secondary current: 5 or 1Aac
 Rated load 1, 2.5, 5.0, 10, 30VA
Accuracy 0.5, 1.0, 3.0 Class
Rated Short-time thermal current (Ith) 20In
Rated Dynamic current (Idyn) 2.5Ith
Case Material  UL flame retardant rating 94-V0
Highest Voltage for Equipment Um (rms) 720 Vac
Rated Power-Frequency Withstand Voltage(rms) 3,000 Vac 
Frequency Range: 50/60Hz
Operating Temperature  -15ºC to 50ºC
Standard IEC 60044-1
 Accessories Supplied with feet for base mounting if required
Certification RoHS compliant CE&ETL approved
 
 
GWSCCTSB Series Split Core Current Transformer  (Features)
Low cost
5 standard sizes
Split core design, safer, easier installation, and portable
GWSCCT Series Split Core Current Transformer   (Applications)
Current, power, energy, monitoring devices
Relay protection devices
Power Factor Correction devices
 
 
Typical Products 
Part
Number
Rated Input/Oput (A) Frequency
( Hz )
Accuracy
Class
Outline 
Dimensions
(mm)
L-W-H
GWSCCT0203 Input:100,150,200,250,300,400
Output:5 or 1
50~400 0.5
1
3
105.0-89.0-40.0
GWSCCT0508 Input:250,300,400,500,600,750,
           800,1000
Output:1or5
50~400 0.5
1
3
145.0-114-48.0
SWSCCT0512 Input:600,700,1000,1250,1500,
           2000,2500,3000
Output:1or5
50~400 0.5
1
3
192.0-143-49.0
GWSCCT0812 Input:500,600,750,800,1000,1200,
           1250,1500
Output:1or5
50~400 0.5
1
3
185.0-144-48.0
GWSCCCT0816 Input:1000,1200,1500,2000,3000,
     4000,5000
Output:1or5
50~400 0.5
1
3
247-176-52.0



5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays    
Output secondary 5A split core current transformer :
Model 1:
GWSCCTSB0203
Turn ratio: 100:5A  150:5A   200:5A   250:5A  300:5A 400:5A current transformer China

Model 2:
GWSCCTSB0508
Turn ratio:250:5A 300:5A 400:5A 500:5A 600:5A 750:5A 1000:5A split core transformer
Model 3:
GWSCCTSB0512
Turn Ratio:600:5A 750:5A 1000:5A 1250:5A 1500:5A 2000:5A 3000:5A current CT
Model 4:
GWSCCTSB0812
Turn ratio: 500:5A600:5A 750:5A 1000:5A 1250:5A 1500:5A split core China 

Model 5:
GWSCCTSB0816
Turn Ratio:500:5A 600:5A 750:5A 1000:5A 1250:5A 1500:5A high quality split core current transformer with ROHS ,ETL approval.
 
Output secondary rated 1A split transformer :

Model 1: GWSCCT0203
Turn ratio :100:1A  150:1A 200:1A 250:1A 300:1A 400:1A split core CT
Model 2: GWSCCT0508
Turn ratio: 200:1A 300:1A 400:1A 500:1A 600:1A 750:1A 1000:1A
Model 3: GWSCCT0512 
Turn Ratio:500:1A 600:1A 750:1A 1000:1A 1250:1A 1500:1A 2000:1A 3000:1A 
Model No.: GWSCCT0812
Model No.GWSCCT0816
Turn ratio: 600:1A 750:1A 1000:1A 1250:1A 1500:1A 2000:1A 2500:1A 3000:1A 4000:1A  split transformer ETL made in China

mA or 0.333-3.53V RATED SECONDART OUTPUT :


5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
1 va 2 va 5v 10 15 30VA 0.333-3.53V Output
split core ct/split current transformer for power factor correction;
0.333-3.53v Output split core current transformer 
split current sensor for correction;
0.333-3.53v current transducer/split current sensor for correction
Part
Number
Ratio Measuring Protection Frequency
(Hz)
Outline
Dimensions 
ID-L-W-H
(mm)
Rated Input  Accuracy
Class
Rated Accuracy
Limit
Primary
Current
(A)
Accuracy
Class
GWSCCT010 3000:1 5,10,20,50,75 1.0,3.0 120 5P,10P 50~400 10
-29.4-26.4-41.7
GWSCCT016 75,100,150 0.5,1.0 300 5P,10P 50~400 16
-36.9-39.2-52.9
GWSCCT024 100,150,200,250 0.5,1.0 540 5P,10P 50~400 24
-51.2-47-70.2
GWSCCT035 200,300,400,600 0.5,1.0 600 5P,10P 50~400 35
-65.8-51.2-83.5

 
 
 
0.333-3.53V rated secondary output split core current transformer :
 
Model No 1 :GWSCCT010
Ratio : 3000:1 

Rated input: 5A 10A 20A 50A 75A
Accuracy class: 1.0s  3.0s
Rated primary current :120A
Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A
 
Model No.2 :GWSCCT016
Ratio :3000:1

Rated input: 75A 100A 150A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 300A
Protection : 5 times Protection, 10 times protection 
 
Model No. 3:GWSCCT024
Ratio : 3000:1 
Rated input: 100A 150A 200A 250A 
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 540A
Protection : 5 times Protection, 10 times protection
 
Model No.4:GWSCCT035
Rated input: 200A 300A 400A 600A 

 Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 600A
Protection : 5 times Protection, 10 times protection
Frequency: 50--400Hz
A2. Split Core Current Transformers \mA or 0.333-3.53V Rated Secondary Output 
1.Applications:
 Current, power, energy, monitoring devices;Relay protection devices;Power Factor Correction devices.
2. Specifications:Rated Primary current: 100-5000Aac;Rated Secondary current:5 or 1Aac;Rated load: 1, 2.5, 5.0, 10, 30VA;Accuracy: 0.5, 1.0, 3.0 Class;
3.Rated Short-time thermal current (Ith):20In
Rated Dynamic current (Idyn):2.5Ith;
Case Material: UL flame retardant rating 94-V0;
Highest Voltage for Equipment Um (rms):720 Vac;
Rated Power-Frequency Withstand Voltage;(rms):3,000 Vac 
Frequency Range:50/60Hz;Operating Temperature: -15 to degree;
Standard:IEC 60044-1 .
Other  current transformer :
5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays



The following pictures show you about all finished current transformers in the warehouse which are waiting for packing into boxes. And then they will be packed into export standard cartons with strong pallets so that can make sure the goods safe arrival at your destination place.            

 5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays
5 or 1AAC 1, 2.5, 5.0, 10, 30va 0.5, 1.0 Split Transformer CT Sensor for Protection Relays





 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed
Product Groups
More