Tdrl-902 Telecom Tdr Power Cable Fault Locator 32km

Product Details
Customization: Available
Connectors: USB
Test Mode: Instant Test
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (22)
  • Tdrl-902 Telecom Tdr Power Cable Fault Locator 32km
  • Tdrl-902 Telecom Tdr Power Cable Fault Locator 32km
  • Tdrl-902 Telecom Tdr Power Cable Fault Locator 32km
  • Tdrl-902 Telecom Tdr Power Cable Fault Locator 32km
  • Tdrl-902 Telecom Tdr Power Cable Fault Locator 32km
  • Tdrl-902 Telecom Tdr Power Cable Fault Locator 32km
Find Similar Products

Basic Info.

Model NO.
TDRL-902
Test Region
Unformed
Cable Type
Power
Power
Electricity
Certification
CE, RoHS
Customized
Customized
Color
Orange
Name
Tdrl-902 Tdr Cable Fault Locator
Range
0-8km,16km,32km
Resolution
Max.1m
Unipolarity Impulse
30V
Measurement Dead Zone
1m
Display
128*64 DOT LCD
Dimension
225mmx105mmx50mm
Weight
0.5kg
Transport Package
Export Standard Cartons with Strong Pallets
Specification
CE ROHS
Trademark
grewin
Origin
China
HS Code
850450000
Production Capacity
50000 PCS /Week

Product Description


Name: 0-8km visual Cable Fault Locator Power Meter

 Tdrl-902 Telecom Tdr Power Cable Fault Locator 32km

Tdrl-902 Telecom Tdr Power Cable Fault Locator 32km

This Cable Fault Locator (hereafter referred as locator) can measure the exact fault location such as the broken line, cross faults, earthing, poor insulation and poor contact of the lead covered cables as well as plastic cables.
The highlights for this locator are that it can test numbers of typical faults, features are as follow:
  1. Digital gain Adjustment control to make the gain adjustment very easy.
  2. Digital waveform automatically Identify technique to make sure no test dead zone.
  3. Top grade ARM single chip micro computer can make calculation and judge the fault waveform exactly.
  4. Large colorful LCD display; humanized operation interface; six function keys can do all the tests.
  5. High-energy Li battery, continuous work 10 hours (with special charger).
 

SPECIFICATIONS
 
  1. Max range: 8 km (16km/32km are optional)
  2. Highest resolution: 1m
  3. Dead Zone: 0 m
  4. Power consumption: 1W
  5. Weight(kg): 0.38kg
  6. Dimension(mm): 204×100×36mm3
  7. Working temperature: -15ºC to + 45ºC

Storage temperature: -20ºC~ + 55ºC
 
USB storage (optional): transmit wave form to U disk, and analyze the wave form on computer
 

WORKING PRINCIPLE

Pulse testing is a kind of remote testing method; one can locate the fault point without testing on the field or testing with end-to-end coordination. The principle of the theory is:
The instrument emits a pulse to the line, when the line has faults, the pulse reflection will change. If the come and back time can be measured, the location of the fault point can be detected.
Suppose the pulse transmission velocity in electric cable velocity is V, the come and back time that the pulse travels between the test point and the fault point is T, the fault distance is L, then:

 
  • 2L = V T
 
    • L = V T/2

For example, the sending end transmits a pulse to the cable, after 20μs, the sending end get the reflection pulse. If the pulse transmission velocity in the electric cable is 201m/μs, the fault distance L is

L = 201×20/2 = 2010m


 
TESTING PROCEDURES

Diagnosis of fault characters

To insure the accuracy of the testing of fault point, the testing personnel shall diagnose the fault characters correctly and then choose the most suitable testing mode. The characters of telecom cable faults can be simply divided into the following several kinds:

 
Broken line
 
One or many cable core line are broken.
 
Crossed line

The insulating resistance between the different couple of lines drops and causes the communication amplitude drops.
 
Earthing fault

The insulating resistance between the core line to the lead cover drops and causes low communication quality

Crosstalk noise

When the cable core insulation material is invaded by water or humidity, the insulating resistance will drop and cause low communication quality or even blocks.

Bad insulation

The insulating resistance between different couple of lines and the core drops to a very low level, the communication quality comes under serious influences.

Fault Testing
Cut off the cable to be tested both sides lines or equipment. Make sure the cable to be tested is free of voltage. Using this instrument to do intelligence testing first, if the fault cannot be detected and then you can change to manual testing.

Locating fault point

The tester will Judge the approximate location based on the testing result, then check the cable, cable gland, cross boxes, etc., depending on the actual situation.

AUTO TEST

Press, connect the testing lead line and fault cable line. Press  and then the instrument will show the testing result.

Note: The default setting wave velocity is 200m/ μ s, when you perform intelligence testing, the user shall check whether need to adjust the velocity.

MANUAL TEST

The relevant setting and parameters will demonstrate on the underneath of the display screen. Press  to adjust the setting and parameters.

1) Gain

Press , until "Gain" shows reverse color display. Then press    or

to adjust the amplitude (1~99 adjustable), Press  , the screen will display the wave

after gain adjustment.
 

2) Range

During manual testing, range decides the maximum testing distance of the instrument, so the range value shall be chose as longer than actual length of the cable to

be tested. To adjust the Range, press   , until Range shows reverse color display.

Press or  to adjust the Range.

3) VOP

The precision of the wave velocity, directly affect the precision of the testing result. So the wave velocity shall be calibrated according to the cable characters. Press ,

until VOP shows reverse color display. Then, press  or  to adjust the wave velocity.

Adjust the Range and VOP according to the characters and estimated length of the cable to be tested. Appropriately adjust the wave amplitude to make the waveforms on the display screen to be observed easily. Move the cursor to inflection of the reflected waveform. The fault distance will demonstrate on the underneath of the display screen.

4) Waveform Comparison

Press  until it displays "Press "-" to memory, "+" to both". Now press "" to

save the current waveform; press  to call the original out and compare with the current waveform.
5) Save File (Optional)

 


Press   until it displays "Press "-" or "+" to enter file mode". Now press

or to enter into file save mode.


File save mode can not only test & save cable but also can check & analyze the original waveform.
Save File

When you choose "Current Test", press  to test the current cable. After test is finished, if you want to save file, you can press  until "Press "-" to quit, "+" to

save" appears. Under this condition, press  to normal testing mode; press to save the current file to U-disk.

Check and analyze the previous wave files

Press  until it displays "Press "-" to memory, "+" to both". Now press "" to

save the current waveform; press    to call the original out and compare with the

current waveform. When you are interested in any wave files, you can press  to analyze the current wave file. Under this mode, you can do some operation of the saved file. And the operation method is same as cable operation method. For detailed operation steps, you can refer to the manual testing chapter



VOP REFERENCE TABLE
Items Quantity
   
TDR Cable Fault Locator 1PCS
   
Test Line 2 PCS
   
Charger 1 PCS
   
Carrying Bag 1 PCS
   
User Manual 1 PCS
   
CD with management software 1 PCS (Just for USB function)
   
U-Disk 1 PCS (Just for USB function)
   
 

CHARGING

Current battery power is showed at the top-right of the screen. If the battery power

is inadequate, please use the instrument charger to charge it.

The indicator light of the charge adapter will be red when charging; and it will turn

green after it's fully charged.


PACKING LIST
 
Insulators signal propagation velocity (m/us)
   
High Polymer 168-186
   
Filled polythene 192
   
Polythene 201
   
Teflon 213
   
Paper pulp (0.13uF/Km) 216
   
Foamed polyethylene 246
   
Paper (0.117uF/Km) 264
   
9.5mm coaxial (w) 286
   
9.5mm coaxial(s) 295
   


ATTENTIONS

Keep display screen away from direct sunlight. The contrast ratio of LCD will drop

when temperature higher than 60ºC and it will return to normal when temperature is lower

than 60ºC.

Before testing, better measure the voltage of fault cable to be tested, in order to

avoid test errors or damage the instrument

Do not hit LCD screen.

Company introduction

Tdrl-902 Telecom Tdr Power Cable Fault Locator 32km

1.certification
We have passed ISO9001:2015,CE,SGS approval and IEC report



2.Company profile
Tdrl-902 Telecom Tdr Power Cable Fault Locator 32km


     Tianjin Grewin is concentrating on transformers for 20 Years and complianted by ISO9001:2015,CB,IEC CB,CE etc.We're always pay great attention to its business philosophy "Quality and Honesty First".Grewin is specialized in the design and manufacture of wound components such as transformer,current sensors, chokes etc .windely used in communications,electronics,meters,industrial control,medical equipments and other fields.We are also a provider of power meters and instruments locators. 85% of its products exported to America, Europe, and Asia etc.We sincerely invite you to join us to create a bright future.

3.Terms of Shipment:
Within 10 working days after received related prepayment or L/C.

4.Payment terms:
(1)T/T 100% or 50% deposit by T/T in advance, balance amount to be paid 7 days before
delivery.
(2) By irrevocable L/C at sight, to be issued immediately against confirmed order.
(3)Payment by T/T, if order amount is less than USD 20,000.

5.Warranty:
(1)We provide 1 year warranty.
(2)If the product is defective, please notify us within 3 days of delivery.
(3)All products must be returned on their original condition, in order to qualify for a refund or exchange of goods

6.Why choose us?
Quality and honest first!
A. Flexible service for diffierent transformers with high efficiency performance.
B. Over 40 years experience of transformer designing and producing.
C.100% test of every single product we produce from incoming material checking.
D. UL, CE, ISO9001:2008
E. We offer custom-made transformers, OEM and ODM are welcome
F. We deliver the quality you expect at consistently competitive prices
G.Transformer quality lifetime:10 Years.
H.Specialty Sales service:5 -10 Years

7.Flow chart of trading activities:


NO

Step

Days need

1

Request for quotation

1 day

2

Making quotations

1 day

3

Offer and counter offer

3 days

4

Sending and receiving samples

3-10 days

5

Sample confirmation

3 days

6

Placing a firm order

1 day

7

Paying and receiving the down payment

1-4 day

8

Factory production & Quality inspection

15-20 days

9

Paying and receiving the balance

4 days

10

Delivery of goods

1 days

8.contact
Tianjin Grewin Technology Co.,Ltd. 
Web:transformer.en.made-in-china.com 
Address: 2# MeiNian Plaza No.16 DongTing Road,Hexi Distr,300222,Tianjin China. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier