Integrated High Voltage Signal Generator Cable Fault Location System

Product Details
Customization: Available
Usage: Network Cable Tester, HDMI Cable Tester, Audio Cable Tester, Coaxial Cable Tester, Digital Cable Tester
Certification: CE, RoHS
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (22)
  • Integrated High Voltage Signal Generator Cable Fault Location System
  • Integrated High Voltage Signal Generator Cable Fault Location System
  • Integrated High Voltage Signal Generator Cable Fault Location System
  • Integrated High Voltage Signal Generator Cable Fault Location System
  • Integrated High Voltage Signal Generator Cable Fault Location System
  • Integrated High Voltage Signal Generator Cable Fault Location System
Find Similar Products

Basic Info.

Model NO.
HVSG-500GN
Customized
Non-Customized
Output Surge Voltage
0-35kv, Step Variable
Max. Power Energy
2000j
Power Energy
1000j,500j
Energy-Storage Capacitor
4UF,2UF,10UF
Power Supply
AC 220V.50Hz
Volume
400mm*460mm*300mm
Weight
25 Kgs
Elevation
<4500m
Transport Package
Export Standard Carton or Customize Strong Pallet
Specification
HVSG-500GN Integrated High Voltage Signal Generato
Trademark
Grewin
Origin
China
HS Code
8543201000
Production Capacity
100 PCS Per Month

Product Description

Introduction

The HVSG-500GN Integrated High Voltage Signal Generator is used to offer signal source for the fault locating and pinpointing. Together with the PCLC-901D&PCLD-901P items, it's easy to do:
  1. Impulse current distance measurement
  2. Sound magnetic synchronous method for pinpointing
Integrated High Voltage Signal Generator Cable Fault Location System
Integrated High Voltage Signal Generator Cable Fault Location System
Integrated High Voltage Signal Generator Cable Fault Location System

Integrated High Voltage Signal Generator Cable Fault Location System












Design Features

HVSG-500GN Integrated High Voltage Signal Generator
  1. Integrated design with small size and light
  2. Different sub-models with difference specification
  3. Imported safety case,professional and portable
  4. Built in energy-storage capacitor without HV leak and safe operation
  5. HV directly connect with the faulty cable, easy wiring and safe operation
  6. Built-in high power quick charging and short discharge period
  7. Multiple safety protection support Zero position start and release HV power energy after power off
  8. Multiple working methods of single,period and DC
  9. Step adjustable voltage with LED indication









Tech. Specifications
 
Output surge voltage 0~35KV, Step variable
Max. power energy 2000J
Energy-storage capacitor  4μF
Power AC 220V.50Hz
Volume 400mm×460mm×300mm
Weight 25 kgs
Operating Temperature -10ºC-40ºC
Humidity 5-90%RH
Elevation <4500m











Physical Characteristics
 
  1. The overall organization:




 
  1. Controlling panel
 
1 AC220 port: 220V,50Hz power,above 2kw
2 Power indicator: when device power on the indicator light
3 HV closed/separated: when device power on, the HV circuit is still not work.Only adjust the knob to ZERO position and then press HV closed/separated button, the HV circuit will work.
HV closed indicator light and do HV output.
When device under the HV output status,press HV closed/separated button, the HV circuit will stop work and HV separated indicator will light and meanwhile to discharge the electric charge in built-in HV capacity and tested cable.
Only to adjust the knob to the ZERO position press HV closed.separated button to start HV circuit work again.
4 HV closed indicator: bright when HV circuit work
5 HV separated indicator: bright when HV circuit stop working
6 HV adjust knob: adjust the output voltage according tested cable HV withstand voltage
7 Voltage indication: LED to display the output voltage.
When do one HV impact,if the LED display big value,it means the faulty point is breakdown,if small value,the faulty points is not breakdown.
8 Discharging mode : three different modes of DC,Single and period.
DC is for flashover fault pre-location and common match with the HV adjustment.
Single is for HV resistance fault pre-location. Press Single button to do one time discharge.
Period is for pinpointing. When under this mode,the device will auto discharge according the set time period. Default is 5 seconds.  
9 Single discharge button: when device under the Single mode,press this button to do one discharge and signal output.
It is valid when other mode.



 
  1. Output cable
HV output cable and protection grounding cable is away and be received from the back of device.
 
  1. HV output cable: connect the tested faulty cable and inject the HV and signal into the faulty cable.The red clip is negative HV output,the black clip is tested grounding. When phase-sheath fault to contact the cable sheath by black clip and connect the red clip with faulty core line.And when phase-phase fault, to connect the black clip and read clip with two faulty cores.For safety,there's instruction that can do auto cable discharging when device power off.
* when use this device please make sure to keep far from the output clip and after use, disassemble after discharging and the HV indication is zero.
  1. Protection grounding: it is the device protection grounding point. For safe please make sure device reliable grounding.                                                  Operating method

  2. Integrated High Voltage Signal Generator Cable Fault Location System
    Integrated High Voltage Signal Generator Cable Fault Location System
     
  3. All set devices connection
  4. Phase-earth fault wiring as below

    Phase-phase fault wiring as below:


    Detailed steps:
  5. Connect the power line and HV output line of HVSG-500GN.*when connection, please contact the unused phase together with the testing ground to ground connection. Connect the Protective grounding line to the earth mat to keep a good connection. Meanwhile, connect the discharge rod.
  6. Choose the connect method according requirement. Connect the HV output line of HVSG-500GN with the fault cable. The details refer the matched TDRL -71&TDRL -81 Guide.
  7. Turn the voltage adjustment button to the 'ZERO'position. Connect the power line and start the device, so the 'Power supply' indicator will onlight.
  8. Choose the discharge method according the cable fault:
  9. Flashover fault with small cable current leaking: DC Discharging method.
  10. Other fault: Single mode.
  11. Pinpointing: Period mode
  12. Check the line connection and the device working mode again.
  13. Adjust the HV adjustment button to ZERO position and the Zero indicator will be bright. Press HV closed /separated button. The HV closed indicator indicator is light and it means the HV input power in connected.
  14. According the cable voltage withstanding lever to spin the knob and make HV reach required HV level. After the HV knob leaves the ZERO position the Zero indicator light off.
  15. The device will discharge according the work method you chose. SINGLE method is used for cable fault pre-locating. Press this button and will begin a discharge. PERIOD is for cable fault pinpointing. Period is 5 seconds.  
  16. When distance measuring and pinpointing, we could judge whether the fault point is breakdown from HV indicator:
  17. HV indicator vary greatly : breakdown
  18. HV indicator vary little:not breakdown and we need to repeat the HV output and rise the output voltage.
  19. After operating to press the HV closed/separated button to release the energy in the device. Press ON/OFF button to turn down the device. After this, use the discharge rod to release the current of the HV output side again.
  20. After current releasing, don't remove the connected wire before the HV output display needle pointing to the 'ZERO' position




  21. Security warming
  22. The max voltage of the machine is 35kV.Please take care about this!
  23. When the device working, please keep away from the output clamp!
  24. Please don't insert the metallic items into the device!
  25. Disassemble is forbidden to avoid heavy current shock



  26.       Contact with us if any problems during the using!                                                       

    Company introduction
    Integrated High Voltage Signal Generator Cable Fault Location System

    Certificate:


    Integrated High Voltage Signal Generator Cable Fault Location System


    Contact:
    Grewin.Beyond
    Tianjin Grewin Technology Co.,Ltd.
    Web:transformer.en.made-in-china.com

     
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More