35kv Hv Impulse Discharge Generator Cable Fault Tester

Product Details
Customization: Available
Connectors: USB
Test Mode: Instant Test
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (22)
  • 35kv Hv Impulse Discharge Generator Cable Fault Tester
  • 35kv Hv Impulse Discharge Generator Cable Fault Tester
  • 35kv Hv Impulse Discharge Generator Cable Fault Tester
  • 35kv Hv Impulse Discharge Generator Cable Fault Tester
  • 35kv Hv Impulse Discharge Generator Cable Fault Tester
  • 35kv Hv Impulse Discharge Generator Cable Fault Tester
Find Similar Products

Basic Info.

Model NO.
HVSG-600GN-4
Test Region
Unformed
Cable Type
Power
Power
Electricity
Certification
CE, RoHS
Customized
Non-Customized
Color
Orange
Display
Digital
Warranty
with Warranty
Power Source
DC 100V-300V
Installation
Portable Precise
Function
Provide Signal
Type
Cable Fault Tester
Environment
High Voltge Outside
Weight
36kgs
Output Surge Voltage
35kv
Max. Power Energy
2450j
Specificaion
4UF
Transport Package
Export Standard Carton or Customize Strong Pallet
Specification
RoHS, CE
Trademark
Grewin
Origin
China
HS Code
90289010
Production Capacity
400 PCS Per Month

Product Description

Product Description:

1.Introduction

  1. Features
  1. Instrument has a high voltage side, low voltage side and supply-side triple over-current, over-voltage and over-heating protection functions;
  2. Uniform impulse discharge.
  3. Short circuit protection, the instrument can work when HV output is short circuit to ground.
  4. 1.5 grade clear current voltage meter.
  5. Accurate high voltage side , real-time display, connecting microampere meter high side can act as a DC high voltage generator
  6. With function of overheating protection , zero start protection, safe and reliable.
  7. The unique design of  high voltage measurement. Voltmeter indicates real-time capacitance and voltage in stop status.
  1. Specifications:
  1. Output voltage: 0 ~ 35 kV continuous adjustable.
  2. High pressure partial pressure : voltage accuracy : 1.5
  3. Inner capacitor :4μF
  4. Impact Power: 400W (can be customized )
  5. Discharge power : 2450J
  6. Discharging time:1-10 seconds
  7. Over-temperature protection:85ºC
  8. Volume: 420L×325W×480H
  9. Weight: No more than 33kg
  10. Environment  temperature : -20~+50ºC
  11. Working power source : AC 220V±10% 50Hz±2Hz

35kv Hv Impulse Discharge Generator Cable Fault Tester
Related Products

1.The HVSG-500G Integrated High Voltage Signal Generator is used to offer signal source for the fault locating and pinpointing. Together with the
 PCLC 910D&PCLD-901P items, it's easy to do:

           (1)Impulse current distance measurement 
           (2)Sound magnetic synchronous method for pinpointing       
 
Output surge voltage 0~35KV, Step variable
Max. power energy 2000J
Energy-storage capacitor  4μF
Power AC 220V.50Hz
Volume 400mm×460mm×300mm
Weight 25 kgs
Operating Temperature -10ºC-40ºC
Humidity 5-90%RH
Elevation <4500m

2.We have two ranges about high voltage generator as below:
 
1). 0-10KV 500J 10uf 
2). 0-32kv  1000J 2uf
3)0-35KV 2000J 4uf

                       
3.Function feature:
Integrated design with small size and light 
Different sub-models with difference specification
Imported safety case,professional and portable
Built in energy-storage capacitor without HV leak and safe operation
HV directly connect with the faulty cable, easy wiring and safe operation
Built-in high power quick charging and short discharge period
Multiple safety protection support Zero position start and release HV power energy after power off
Multiple working methods of single,period and DC
Step adjustable voltage with LED indication
4.Specification
Output surge voltage 0~35KV, Continuously variable
Max. power energy 1000J
Energy-storage capacitor  2μF
Power AC 220V.50Hz or 230V  60HZ
Volume 400mm×460mm×300mm
Weight 25 kgs
Operating Temperature  -10ºC-40ºC
Humidity 5-90%RH
Elevation <4500m

 
                       
5.Product Pictures:
HVSG-500GN-2  1000J 4UF CABLE FUALT LOCATING HV SIGNAL GENERATOR
 
35kv Hv Impulse Discharge Generator Cable Fault Tester

6. Our pipe locator has below advantages:
 
1.The max transmitter power is 12W .
2.We add a booster to increase the transmission signal strength and make the test more accurate.
3. Frequency:
Grewin:GWRCI-601P have multi frequency and max frequency can up to 197Khz
 We can give you warranty period and good after sales sevices. 


35kv Hv Impulse Discharge Generator Cable Fault Tester

7.PIN POINTER CABLE FAULT LOCATOR ADVANTAGES:

1.The test accuracy is < 0.1M and high class in our market ;
2. It is also use HUAWEI charger etc. 
3.Sound magnetic synchronous method and filter etc. 

35kv Hv Impulse Discharge Generator Cable Fault Tester


8. PCLC-901D Pre-locator:

1. Work mode: TDR,ICM, MIM;
2.HMI: Ultra-high brightness and support touch screen and download PC datas and monitoring;
3.Max test range: 100KM

35kv Hv Impulse Discharge Generator Cable Fault Tester35kv Hv Impulse Discharge Generator Cable Fault Tester
35kv Hv Impulse Discharge Generator Cable Fault Tester35kv Hv Impulse Discharge Generator Cable Fault Tester35kv Hv Impulse Discharge Generator Cable Fault Tester35kv Hv Impulse Discharge Generator Cable Fault Tester35kv Hv Impulse Discharge Generator Cable Fault Tester

Company introduction:

35kv Hv Impulse Discharge Generator Cable Fault Tester3.Terms of Shipment:
Within 10 working days after received related prepayment or L/C.

4.Payment terms:
(1)T/T 100% or 50% deposit by T/T in advance, balance amount to be paid 7 days before
delivery.
(2) By irrevocable L/C at sight, to be issued immediately against confirmed order.
(3)Payment by T/T, if order amount is less than USD 20,000.

5.Warranty:
(1)We provide 1 year warranty.
(2)If the product is defective, please notify us within 3 days of delivery.
(3)All products must be returned on their original condition, in order to qualify for a refund or exchange of goods

6.Why choose us?
Quality and honest first!
A. Flexible service for diffierent transformers with high efficiency performance.
B. Over 40 years experience of transformer designing and producing.
C.100% test of every single product we produce from incoming material checking.
D. UL, CE, ISO9001:2008
E. We offer custom-made transformers, OEM and ODM are welcome
F. We deliver the quality you expect at consistently competitive prices
G.Transformer quality lifetime:10 Years.
H.Specialty Sales service:5 -10 Years

7.Flow chart of trading activities:

 

NO

Step

Days need

1

Request for quotation

1 day

2

Making quotations

1 day

3

Offer and counter offer

3 days

4

Sending and receiving samples

10 days

5

Sample confirmation

10days

6

Placing a firm order

1 day

7

Paying and receiving the down payment

1-4 day

8

Factory production & Quality inspection

15-20 days

9

Paying and receiving the balance

4 days

10

Delivery of goods

1 days

8.CONTACT:
Alice.Lee
Tianjin Grewin Technology Co.,Ltd.
Web:transformer.en.made-in-china.com  
    

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed
Product Groups
More