• Magnetic Coil Turns Tester Machine
  • Magnetic Coil Turns Tester Machine
  • Magnetic Coil Turns Tester Machine
  • Magnetic Coil Turns Tester Machine
  • Magnetic Coil Turns Tester Machine

Magnetic Coil Turns Tester Machine

Certification: RoHS, CE, ISO
Sensor’s Type: Ф9.5 Ф6 Ф4
Resistance Measurement Accuracy: 0.2%
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Magnetic Coil Turns Tester Machine pictures & photos
Magnetic Coil Turns Tester Machine
US $500-5,000 / Set
Min. Order: 1 Set
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Tianjin, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (22)

Basic Info.

Model NO.
GW 2100R
Winding Measurement Range
1-30000
Winding Measurement Accuracy
500~30000 Circle ±0.3%
Winding Basic Measurement Speed
1.5 Measurements /Second
Resistance Measurement Range
100uΩ-20KΩ
Resistance Basic Measurement Speed
3 Times /Second
Transport Package
Export Standard Carton or Customize Strong Pallet
Specification
GW-2100R
Trademark
Grewin
Origin
China
HS Code
85043190
Production Capacity
100PCS

Product Description

NAME:  GW-2100R  Magnetic coil turns tester  

Specifications
Sensor's type Ф9.5    Ф6     Ф4
Winding's shape Inner diameter >Ф4mm outer diameter<120mm height<110mm
Winding measurement range 1~30000
Winding measurement accuracy 500~30000 circle ±0.3%
Winding basic measurement speed 1.5 measurements /second
Resistance measurement range 100uΩ-20kΩ
Resistance basic measurement speed 3 times /second
Resistance measurement accuracy 0.2%
Range mode Auto selection
Display mode 6-digit LED
Alarm selection Short-circuit ,phase ,quiet
Dimensions (W*H*D) 335×320×290mm
Weight Approx.6kg
Working temperature & humidity 0ºC-40ºC,≤90%RH
Power requirement 198-242VAC 47.5-52.5HZ
Power consumption ≤30VA



Summarize
  1. Product Brief:
  GW2100/GW2100R winding turns test has applied the latest measuring techniques in this field. It has stabilizing performance and good quality. This series of instrument can test various winding turns and shown the DCR value of copper winding resistance (The testing functions only when it is GW2100R). This instrument is applied to test various winding turns such as electric machine, transformer, electric machine winding, and relay coil. The instrument have some characteristics such as intelligent, novel in the appearance, and high test precision, fast speed, widely range and easily to operate. There is no need of calibrating and renewing the range so it will improve the test efficiency greatly.

2. Technical indicators:
2.1 Working environment:
Temperature   0ºC~40ºC
Humidity    ≤90℅RH
Atmospheric pressure 86~104Pa
2.2 Turns testing
2.2.1 The range of turns testing;
 1 ring~30000 ring
2.2.2 Measurement error:
The range of winding turns Measurement error
1~200 ±0.1℅±1 Word
201~1000 ±0.2℅±1 Word
1001~5000 ±0.3℅±2 Word
5001~30000 ±0.5℅±6 Word
2.2.3 Turns dimensions:
Inside diameter>4.5mm, Height<100mm,Outside diameter<100mm(The special sizes could be customs made)
2.3 DCR test(Only GW2100R)
2.3.1 Range:
Automatic selecting
2.3.2 Test current:
0.1mA,1mA,10mA,100 mA Four shifting gears automatic selecting
2.3.3 The test range of resistance:
100uΩ~20kΩ
2.3.4 Measurement error:
Resistance range Measurement error
0.1Ω~0.9999Ω ±0.7℅±2 Word
1Ω~19.99Ω ±0.5℅±1 Word
20Ω~19.99KΩ ±0.3℅±1 Word
   2.4 Operating voltage:
220(1±10%) V AC, 50Hz (1±5%)
2.5 External dimensions:
335mm×320mm×290mm
2.6 Weight:
About 6kg

Panel instructions
1.The front panel drawing(GW2100R)
Magnetic Coil Turns Tester Machine
Magnetic Coil Turns Tester Machine2.The back panel Drawing
Magnetic Coil Turns Tester MachineTo explain the label on front and back panel as detail as follow:
Label Name Functional instruction
The front panel instruction
1 Indicator lamp turnoff, short indicator
2 Display window Display turns or the value of resistance test
3 Indicator lamp(GW2100R) Turns or the resistance unit indication
4 The key-press of  parameter (GW2100R) Select test turns or resistance
 
5 The key-press of Clear(GW2100R) The clear for testing resistance short
6 Power switch Used in on (1)or off(0) instrument import power
7 The key-press of Phase, turnoff, silent The mode used in select alarm setup
8 The indicator lamp for alarm setup state To indicate the alarm setup state
9 Test transducer Be used in measurement the winding turns
10 Tumbler anti-clockwise Open it to set the measured turns
The back panel description
11 Fuse Be used in overcurrent protection of instrument, please use the 1A fuse
12 Test port To connect GW26004A connecting line test turns or DCR outside
13 Communication joint Be use in leave factor check
14 Power socket Be use in connect 220V power line
15 Nameplate To mark the manufacturing company, date and instrument No.etc



Operating instructions
    1. Preparation for measuring
When plug power line and testing line, opening the power switch on "1", and the display and indicator lamp will be on. The display will shown "GW2100" (matches with GW2100) or "GW2100R" (matches with GW2100R) at one minutes later, the display shown"OPEN" (The state of measurement turns) or "-OU-"(The state of measurement resistance) after it flickers for about 15min. In order to test the instrument accurately, it should to be preheating 15min
    1. Preferences(Only GW2100R)
To select test content according with actual measurement and the key of "PARA" can be pressed to conversion between turns test and DCR Test.
3.   Measuring of turns
3.1   Select method of alarm setup (this selected method only applicable to the testing of turns, when testing the DCR, select this method is invalid);
Selections of message ring correspond respectively with the key" Phase"," turnoff", "silent" and matching indicator lamp. If the corresponding set testing happens in measurement, the inside hummer will go on ringing and inform the testers about the respective alarm.  
    When the phase key is pressed and the corresponding phase light is on, it suggests that the windings tolerate the phase. Interrupted alarm rings when the opposition is -
Press the key" turnoff", the corresponding indicator lamp on, it is shown that the tested winding is turnoff (open). Otherwise, the interrupted alarm rings when it fails to connect, at the same time the "turnoff" lamp is on at the upper left of the instrument.The display will shown "-OPEN-"in testing open anytime;
Press the key" silent", the corresponding indicator lamp on, the alarm still rings as it short.
    1.   Measuring of turns::
To running the tumbler of transducer to propriety location (the corner <=45o) in counter-clockwise direction and to set the testing winding into the turns test transducer what is vertical to the instrument plane, then running the tumbler of transducer to close the vertical transducer in clockwise direction and then connect the testing clips and testing winding, the value what the display shown is the practice turns of testing winding value. Repeat above process and test next winding.  
6.DCR test (Only GW2100R)
      Press the" PARA" key into the state of measurement of resistance, and the display shown-OU-.
6.1  Clear:
The testing clips is short as following drawing, press the "clear" key to clear the base data what it is be applied in measurement resistance. Magnetic Coil Turns Tester Machine
    1. Measuring of resistance:
To connect the testing resistance into testing line, the instrument will automatic select span according with the size of resistance value and The LED digital display shown the testing value; select the measurement of resistance after turns testing finished, and can read out the copper resistance of measurement winding. The tested winding will not be set into winding test transducer in measurement of resistance.
Notice
  1. Dot not lay the instrument near to the larger magnetic field, it will effect the normally test of instrument
  2. If the testing winding has short by itself, it will affect precision.
  3. The testing winding will be laid in centre of transducer to avoid affecting the test precision of the instrument.
  4. Don't through the test line into transducer; it will affect the results of testing
  5. The testing line is wearing parts, if the instrument do not have nicely measure or do not test normality, please check the testing line break off whether or not, bad connection or the other failure.
  6. The testing element should put and down lightly, to avoid impacting transducer, the rocker of transducer running should not exceed 45O and running the rocker of transducer with high power should damage the transducer forever.
  7. To protect transducer in transporting and handling the instrument..


PRODUCT:
Magnetic Coil Turns Tester Machine
Magnetic Coil Turns Tester MachineMagnetic Coil Turns Tester Machine
Company Information and Profile
We-TIANJIN GREWIN GROUP is expert in machines lines for more than 31 Years. Our Grewin have ISO9001:2015 approvals.
Why Choose Us
Service tenet
Provide you the best service with "fast + satisfactory + safe".
Warranty period:
12 months long after the user received the product.
Warranty items:
Only for abnormal breakdown caused by the machine design or manufacture defect,free repair and accessory will be provided.

Technology service ability:
All service engineers with many years experience are gotten special technology training, who can deal with various breakdown problem.
Guide the user to use accurately and how to maintain the product.
Provide free consultation about production process technology of electronic products.

Service after sell: 
In order to guarantee the machine used normally, we'd have training on how to operate, use and maintain our product by English manual, video, guiding on line.

Use instruction:
Apply for the right complete size of product, otherwise, the wrong dimensions will affect the use effect.
Do ensure using the product accord to the use instruction completely.Do not exceed the scope of application of the products.
Maintain the product after use,Damp proof, rust proof, leak proof, explosion-proof, regular maintenance and inspection should be taken care. All done help to extend the use period.

Contect us
Tell us your toroidal coil of data as below please:
1.toroid core outside diameter before winding?
2.toroid core inside diameter before winding?
3.toroid core height before winding?
4.how many windings on this core?
5.how many tape windings total on this toroidal coil?
6.how about the tape width of each tape winding?
7.how many turns of each tape winding?
8.provide pictures of product which is better.


Clara            
Tianjin Grewin Technology Co.,Ltd.
Web:transformer.en.made-in-china.com
Address: 2# MeiNian Plaza No.16 DongTing Road,Hexi Distr,300222,Tianjin China.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now