Customization: | Available |
---|---|
Connectors: | USB |
Usage: | Network Cable Tester, HDMI Cable Tester, Audio Cable Tester, Coaxial Cable Tester, Digital Cable Tester |
Still deciding? Get samples of US$ 2300/Set
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product name: PCLD-904P Cable Fault Detection Instruments pinpointer cable fault locator
INTRODUCTION
PCLD-904P Digital Power Cable Fault Pin-pointer is an easy opera
tion device used to pinpoint the fault point. It integrated the function of acoustic magnetic synchronization method, the step voltage method, the magnetic field strength method to make the pinpointing accuracy.
1.DESIGN FEATHER
1) acoustic magnetic synchronous pin-pointing:
a) acoustic channel
l Bandwidth:
all-pass: 80Hz~1500Hz
low-pass: 80Hz~400Hz
high-pass: 200Hz~1500Hz
band-pass: 150Hz~600Hz
b) Signal gain: ≥80dB
c) Accuracy: 0.1m
2) Background noise reduction mode: support noise reduction, no noise reduction, adaptive noise reduction
a) Magnification times: >80db
3) Power supply:
a) Battery: built-in Li-ion battery series,3.7V,6700mAH
b) Continuous work time above 9 hours
c) Charger: input AC220V±10%,50Hz;output 8.4V,output 5V/2A
4) Display method: 800x470 dot LCD, screen semitransparent & Semi Gloss to make sure clear display under the sun
5) Size: 230mm×127mm×55m
6) Weight: 230mm×127mm×55m
7) Use environment: -10ºC~40ºC,5-90% RH, elevation <4500m
PHYSICAL CHARACTERISTICS
1.STANDARD CONFIGURATION:
Main unit x1
acoustic magnetic synchronous sensors x1
High performance anti-noise earphone x1
Connection line x 1
Charger x1
2.MAIN UNIT PANEL
Details:
NO | NAME | INTRODUCTION | |
1 | LCD | ||
l [set/power]: long time press to start and short time press | |||
to enter the setting interface | |||
l [display mode]:adjust the display mode | |||
l [mute]:control the headphone acoustic output | |||
l [noise reduction mode]:adjust the noise reduction mode | |||
l [multiple function button]: | |||
2 | KEY BOARD | [up button]&[down button]: adjust the acoustic gain | |
[right button] &[left button]:waveform mode to adjust the | |||
cursor or adjust the magnetic field trigger value ,use the | |||
middle button to switch | |||
l [middle button] after close the auto magnetic filed to | |||
switch the left/right button to adjust the cursor or | |||
magnetic filed trigger value | |||
3 | USB CHARGING PORT AND | Red light: charging | |
CHARGING INDICATION | Green light: charge complete | ||
4 | HEADPHONE INPUT | Connect with the headphone | |
5 | SIGNAL INPUT | Use the signal line to connect with the sensor |
NO | NAME | INTRODUCTION | |
1 | Pole | Install method: insert into the open hole and rotate the pole as one quarter | |
turn | |||
2 | Signal port | Use to contact with the main unit with signal line | |
3 | Breather valve | ||
4 | Long probe | Used for the lawn or soft ground. Remove it and install in the screw hole in | |
the bottom | |||
OPERATION AND FUNCTION INTRODUCTION
PCLD-904P support both the acoustic-magnetic synchronization pinpointing.
The acoustic-magnetic synchronization pinpointing support both intelligent pinpointing and waveform pinpointing. When use the intelligent pinpointing method, device will auto display the acoustic-magnetic delay value and when use the waveform pinpointing method, we need to make sure the cursor position and measure the delay value.
1. ACOUSTIC-MAGNETIC SYNCHRONIZATION INTERFACE AND FUNCTION
Principle:
Electromagnetic signal transmit by light speed and the time transmit from cable to the sensor could be ignore. The acoustic transmission speed is much lower only several hundred per second. So we can distinguish the faulty points distance by the time difference between magnetic signal and the acoustic signal.
There are two interfaces, intelligent pinpointing and waveform pinpointing interface when use the acoustic-magnetic pinpointing method. The intelligent pinpointing will display the acoustic-magnetic value by intelligent calculation method. It makes the pinpointing more easy and quicker, and need low requirement for the user.
Device also keep a traditional interface which more suitable for the profession staffs with experience. Then the user need to measure the acoustic-magnetic delay value by the cursor position. Refer below display interface:
Pictures:
Along with the low-voltage pulse reflectometry, our systems implement advanced high-voltage pre-location technologies that allow to determine the distance to faults of various types with a minimal harmful effect on the cable lines.High level of safety during the testing with our cable test vans and mobile systems is ensured by built-in protection against overcurrent, overvoltage and overheating, as well as by the use of a continuous grounding monitoring, vehicle door closure sensors and self-health check monitoring.
High speed sample system and high bandwidth input circuit are integrated in the tester to get the exact reflection curve of signal so that the distance of fault point to signal sample point can be calculated in high accuracy and high resolution Special sound location tester configuration can be applied to locate the fault point more exactly.
The cable fault tester is suitable for measuring power cables, high-frequency coaxial cables, local telephone cables, street lamp cables, low-resistance of short-circuit, open-circuit disconnection faults, and various materials of various materials with different cross-sections and different media. Leakage and high resistance flashover faults. A powerful cable management system that automatically generates test reports.
It can test a variety of 35KV under different voltage grade, different sections, different media and all kinds of material of power cable faults, including: open circuit, short circuit, low resistance, high resistance, high resistance leak flashover fault.
It can be any cable length measurement of radio wave propagation in the known speed.It can test the power cables buried path and buried depth.route tracing evaluation of electric lines and cables.
Company introduction
Certificate:
3.Terms of Shipment:
Within 10 working days after received related prepayment or L/C.
4.Payment terms:
(1)T/T 100% or 50% deposit by T/T in advance, balance amount to be paid 7 days before
delivery.
(2) By irrevocable L/C at sight, to be issued immediately against confirmed order.
(3)Payment by T/T, if order amount is less than USD 20,000.
5.Warranty:
(1)We provide 1 year warranty.
(2)If the product is defective, please notify us within 3 days of delivery.
(3)All products must be returned on their original condition, in order to qualify for a refund or exchange of goods
6.Why choose us?
Quality and honest first!
A. Flexible service for diffierent transformers with high efficiency performance.
B. Over 40 years experience of transformer designing and producing.
C.100% test of every single product we produce from incoming material checking.
D. UL, CE, ISO9001:2008
E. We offer custom-made transformers, OEM and ODM are welcome
F. We deliver the quality you expect at consistently competitive prices
G.Transformer quality lifetime:10 Years.
H.Specialty Sales service:5 -10 Years
7.Flow chart of trading activities:
NO |
Step |
Days need |
1 |
Request for quotation |
1 day |
2 |
Making quotations |
1 day |
3 |
Offer and counter offer |
3 days |
4 |
Sending and receiving samples |
3-10 days |
5 |
Sample confirmation |
3 days |
6 |
Placing a firm order |
1 day |
7 |
Paying and receiving the down payment |
1-4 day |
8 |
Factory production & Quality inspection |
15-20 days |
9 |
Paying and receiving the balance |
4 days |
10 |
Delivery of goods |
1 days |
8.Contact:
Grewin.Beyond
Tianjin Grewin Technology Co.,Ltd.
Web:transformer.en.made-in-china.com