1.GWCTP1535 0.1A-1000A:
Current probe(specifications) |
Rated Primary current |
0.1A-1000A |
Output signal |
mA/A or mV/A |
Maximum Non-Destructive Current |
2000A |
Basic Accuracy |
1% |
Safety |
CAT III 600V |
Dielectric Resistance |
1000MOhms @ 500 Vdc |
Case Material |
Polypropylene resinUL flame retardant rating 94-V0 |
Voltage rank |
600Vac(isolated condition), 30Vac(bareness condition) |
Maximum voltage |
600Vac |
Useable frequency |
10Hz - 100kHz |
Maximum Cable Diameter |
2.05 inches (52 mm) |
Dimensions |
4.37x8.5 x1.77 in. (111x216x45 mm) |
Operating Temperature |
-10ºC to +50ºC |
Standard |
IEC 60044-1 |
Accessories |
Supplied with feet for base mounting if required |
Certification |
RoHS compliant CE&ETL approved |
Current probe(features) |
Good appearance |
Low cost |
5 standard sizes |
Clamp-on core design,safer,easier installation, portable |
Both Silicon Steel & Nickel Alloy cores available |
Current or three specs voltage output signal |
Current probe(applications) |
Current, power energy,monitoring devices |
Power Factor Correction devices |
Oscilloscope and harmonic waves analyzer |
Part number |
Input current |
Rated Output |
Frequency
(Hz) |
Secondary
Burden
Resistance |
Accuracy
Class |
GWCTP1535 |
0.5-1000A |
1mA/A |
40-1KHZ |
≤10 Ohms |
1% |
400-1000A |
5A,1A |
50/60HZ |
≤2VA |
1% |
0.1-10A |
100mV/A |
10-1000K |
≥100KOhms |
3%±10mV |
0.1-100A |
10mV/A |
2%±5mV |
1-1000A |
1mV/A |
1%±1mV |
0.5-1000A |
4-20mA |
50/60HZ |
≤100 Ohms |
1% |
GWQCT03 Clamp sensor Specification :
Technical datas:
Rated primary current: |
Max 500A AC |
Output voltage: |
333 mV AC |
Amplitude accuracy: |
±0.5% rdg.±0.1%f.s. (f.s.:500A, 45Hz - 66Hz, Primary conductor in the enter) |
Phase accuracy |
±1°(10~100%I1n)(45 Hz - 5 kHz) |
The amplitude frequency characteristic |
±1% (45 Hz - 5 kHz) ( Deviation Accuracy) |
Conductor impact |
±0.5%(off-center) |
The influence of external electromagnetic fields |
≤0.1 A(in AC 400A /M electromagnetic fields) |
Maximum input current |
550A AC continuous (45-66 HZ Ambient temperature 50°C) |
Temperature coefficient |
0.02 %reading data /°C |
Dielectric strength |
5312 V ACrms /continuous 15s (circuits- core) |
Maximum rated voltage |
600V ACrms |
Woring temperature& humidity |
0 to 50°C (32 - 122°F), ≤80%RH (No condensate) |
Woring temperature& humidity |
-10 to 60°C (14 - 140°F), ≤80%RH (No condensate) |
Indoor using and up to 2000m above sea level |
Standards |
sacurity:EN61010 - 2 -032:2002 , CAT III,contamination II
EMC:EN61326:1997+A1:1998+A2:2001+A3:2003(Class A) |
Measure conductor diameter |
≤Φ46mm |
Cable length |
2m |
Size |
About 78W x 160H x 40D mm(excluding protruding parts) |
weight |
About 380g |
Accessory |
Instrution manul one piece |
f.s. :Maximum display datas or scale length
rdg:Reading value (the value of the current is measured and displayed in the measurement of the product)
We can produce following similar clamp on current transformer GWCTC Series :
Clamp on current transformer(applications) |
Silicon Steel cores provide moderate accuracy and lower cost for appropriate current measurement |
Nickel Alloy cores are suitable for applications that require the highest accuracy with minimal
phase angle error.Applications would include electric power quality monitoring devices |
Clamp on current transformer(specifications) |
Rated Primary current |
1-200A |
Turn ratio |
1:1000 1:2000 1:2500 |
Output |
0.333V 1.5V |
Accuracy |
0.1, 0.2 ,1.0 Class |
Second burden(Ohms) |
<5, <50 ,>100k |
Dielectric Resistance |
1000MOhms @ 500 Vdc |
Case Material |
Polypropylene resinUL flame retardant rating 94-V0 |
Voltage rank |
600Vac(isolated condition), 30Vac(bareness condition) |
High Potential |
2500Volts/min |
Frequency Range: |
50/60Hz |
Operating Temperature |
-25ºC to +70ºC |
Standard |
IEC 60044-1 |
Accessories |
Supplied with feet for base mounting if required |
Certification |
RoHS compliant CE&ETL approved |
|
Part
Number |
Rated
Input
(A) |
Turn
Ratio |
Frequency
( Hz ) |
Secondary
Burden
Resistance
(Ohms) |
Accuracy
Class |
Outline
Dimensions
(mm) |
|
GWCTP0080N |
1~50 |
1:1000
1:2000
1:2500
... |
50 to 400 |
≤50 |
0.1
0.2 |
ID-L-W-H
8.0-46.0-27.0-171 |
|
GWCTP0130N |
5~200 |
50 to 400 |
≤5 |
0.1
0.2 |
ID-L-W-H
13.0-52.0-27.0-174 |
|
GWCTP0200N |
5~200 |
50 to 400 |
≤5 |
0.1
0.2 |
ID-L-W-H
20.0-52.0-27.0-180 |
|
GWLCTP-0250 |
Input:100A
Output:0.333,
1.5V |
-- |
50 to 1K |
≥100k |
1.0 |
ID-L-W-H
25.0-50.0-19.5-87 |
Tianjin Grewin Technology Co.,Ltd |
Clamp on current transformer(features) |
Low cost |
5 standard sizes |
Clamp-on core design,safer,easier installation, portable |
Both Silicon Steel & Nickel Alloy cores available |
Clamp on current transformer(applications) |
Silicon Steel cores provide moderate accuracy and lower cost for appropriate current measurement |
Nickel Alloy cores are suitable for applications that require the highest accuracy with minimal phase angle error. Applications would include electric power quality monitoring devices |
Contact Information:
Tianjin Grewin Technology Co.,Ltd.
Web: transformer.en.made-in-china.com