• Overhead Line Grounding Fault Locator with Good Pinpointing
  • Overhead Line Grounding Fault Locator with Good Pinpointing
  • Overhead Line Grounding Fault Locator with Good Pinpointing
  • Overhead Line Grounding Fault Locator with Good Pinpointing
  • Overhead Line Grounding Fault Locator with Good Pinpointing
  • Overhead Line Grounding Fault Locator with Good Pinpointing

Overhead Line Grounding Fault Locator with Good Pinpointing

Connectors: Overhead Line Grounding Fault Locator
Test Mode: Point Test
Usage: Digital Cable Tester
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Overhead Line Grounding Fault Locator with Good Pinpointing pictures & photos
Overhead Line Grounding Fault Locator with Good Pinpointing
US $999-4,999 / Piece
Min. Order: 1 Piece
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Tianjin, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (22)

Basic Info.

Model NO.
OGFL-200
Test Region
Unformed
Cable Type
Shielded
Power
Electricity
Certification
CE, RoHS, SGS, IEC
Customized
Non-Customized
Color
Red Yellow Orange Locator
Type1
Name: Ogfl-200 Overhead Line Grounding Fault Locat
Location Accuracy
0.2m
Open-Circuit Voltage
Fundamental Wave Valid 0~2800kv
Short-Circuit Current
Fundamental Wave Valid 0~35mA
Output Frequency
1Hz
Communication Distance
≥30m
Transmitter Power
Max. 900 W
Sensor Supply Power
Three AAA Alkaline Batteries
Receiver Supply Power
Five AA Alkaline Batteries
Transmitter Weight
15kg
Transport Package
Export Standard Carton or Customize Strong Pallet
Specification
OGFL-200 Overhead Line Grounding Fault Locator
Trademark
OGFL-200 Overhead Line Grounding Fault Locator
Origin
China
HS Code
9028901000
Production Capacity
4000 PCS Per Month

Product Description


Tianjin Grewin Technology Co.,ltd, who always pay great attention to its business philosophy "Quality and Honesty First". Grewin is specialized in the design and manufacture of wound components such as transformer,current sensors, chokes etc . windely used in communications,electronics,meters,industrial control,medical equipments and other fields.We are also a provider of power meters and instruments locators. 85% of its products exported to America, Europe, and Asia etc. We have passed ISO9001,CE,SGS approval and IEC report and developed good cooperative relationship with valued customers around product quality and value-added service along with the fast efficient solution.Grewin has won a lot of customer's praise.
Overhead Line Grounding Fault Locator with Good Pinpointing
Overhead Line Grounding Fault Locator with Good Pinpointing


Name: OGFL-200 Overhead Line Grounding Fault Locator
 Transmitter
It is used to inject ultralow frequency pulsating DC signal to the fault line to reappear the grounding fault.The current output by the transmitter and through the fault line to ground at the fault point and back to the receiver.

The transmitter panel as below:
Overhead Line Grounding Fault Locator with Good Pinpointing
Power socket: contact with 220V power
Protective tube: change protective tube if needed
Power switch: turn on/off the device
Hon: when turn on the device, press this button when output adjustment on the ZERO position to output HV signal.
HV off: Stop HV output
Zero: indicate that the output voltage on the zero position
Protect: when the device become protect mode, this indicator will be bright to show the device is in protect blocking state. Adjust the Output adjust button to Zero position to reset the indicator.
Output adjust: adjust the output current and voltage. When it on the Zero position, to press HV on button to start the transmitter signal output function.
Protect current: indicate the input current value. If current is over default max. 4A,the device will be stopped. Then it is needed to zero the output adjustment button to set protective circuit to readjustment the current.
Output voltage: indicate the value of output voltage
Earth: earth terminal to contact with the earth line to connect the earth mat.
HV out: connect the fault line. According the local state to clip the switchgear wire or connect the faulty line with rod of patch board 
Test ground: connect with earth mat.

Sensor
It is used to hang on the fault line and test the current signal, and transmit data to the receiver by the wireless mode.
Panel as below:
Overhead Line Grounding Fault Locator with Good Pinpointing
Comm. Indicator: flicker when normal communication; Lighting-off then communication disconnect.
Power indicator: light when normal; Flicker when low battery.
Power on/off: long-time press to turn on the device

Receiver
The receiver is used to receive data and display the result. Panel refer below fig.
Overhead Line Grounding Fault Locator with Good Pinpointing
Certification:
We have abtained VDE,UL,CE,ROHS,ISO9000 Approal and SGS Audit Supplier in China,We guarantee quality is the first
Overhead Line Grounding Fault Locator with Good Pinpointing

Product description:
Good solution of the pinpointing of single phase to earth fault 
 Applies to overhead line small current grounding power system. 
 Use to pinpoint the earth fault when line break down when single phase grounding fault happen
Function introduction: 
1.      Apply to small current neutral grounding distribution power system. 
2.      Used to detect the over head line metallic grounding fault, arc grounding fault, resistance grounding fault and so on. 
3.      Workable for broke down line, apply for branch line 
4.      Ultralow frequency signal to avoid capacitor influence. Easy to find the high resistive fault 
5.      Recreate fault by high voltage signal, easy to locate 
6.      Safe transmitter by black and short-circuit function 
7.      High sensitive sensor, open design and easy to hang on the line 
8.      Wireless transmission, safe and reliable 
9.      Flexible power supply. Transmitter is workable by Utility power and electric generator. Sensor and receiver are by dry battery 
10.   Light and easy to carry 
11.   Receiver has large LCD display interface, which can show the current waveform and current value 
 
 
Specification
1.     Location accuracy:0.2m 
2.     Specification of transmitter:
  open-circuit voltage: fundamental wave valid 0~2800kV
  short-circuit current: fundamental wave valid 0~35mA(impulse DC, peak value 100mA )
  output frequency1Hz 
3.     Communication distance between receiver and transmitter:≥30m 
4.     Transmitter power: AC 220V,or electric generator 
5.     Transmitter power: Max. 900 W 
6.     Sensor supply power: Three AAA alkaline batteries 
7.     Receiver supply power: Five AA alkaline batteries 
8.     Dimension: transmitter 455mmx355mmx310mm
              Sensor 180mmx100mmx35mm
              Receiver 205mmx200mmx35mm 
9.     Weight: transmitter 15kg
              Sensor 0.45kg
              Receiver 0.45kg 
10.  Working condition : 
Temperature -10ºC-40ºC 
Humidity 5-90% 
Elevation ≤4500m 
 
contact information:
 
Bella
Tianjin Grewin Technology Co.,Ltd.
Web:http://grewin-tech.en.made-in-china.com or transformer.en.made-in-china.com 
TEL:86-22-84943756
FAX:86-22-85909471
MT: 86-13116189651

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now